Seeburg 222 selector problems
Just started recently.I make a selection and it goes to a random
selection and starts playing,after I eject that selection,it goes to another random and starts playing.I usually have to eject about 8-10 selections before they are all cleared.I start again,and the same proble.It never starts at the selected records and adds up several other random selection. I started this machine one night after a freeze,the selections wouldn't make,then,after a few minutes,I could make a selection,but the above problem started. I have the manuel,but no troubleshooter tips for this issue. Any help is appreciated |
Ads |
#2
|
|||
|
|||
Seeburg 222 selector problems
Try cleaning the contact block where the pins come in contact while
scanning. A flaky connection on the ground strip in the middle can easily cause the random selection issue. |
#3
|
|||
|
|||
Seeburg 222 selector problems
Tim wrote:
Just started recently.I make a selection and it goes to a random selection and starts playing,after I eject that selection,it goes to another random and starts playing.I usually have to eject about 8-10 selections before they are all cleared.I start again,and the same proble.It never starts at the selected records and adds up several other random selection. I started this machine one night after a freeze,the selections wouldn't make,then,after a few minutes,I could make a selection,but the above problem started. I have the manuel,but no troubleshooter tips for this issue. Any help is appreciated Usually a bad ground, quite often on the little cable with the RCA plug. If you don't know what an RCA plug looks like, do a google images search. I forget if it only goes to the pulse amp or if it goes in and out of a jack on the way. |
#4
|
|||
|
|||
Seeburg 222 selector problems
On Jan 30, 9:05*am, Tony wrote:
Tim wrote: Just started recently.I make a selection and it goes to a random selection and starts playing,after I eject that selection,it goes to another random and starts playing.I usually have to eject about 8-10 selections before they are all cleared.I start again,and the same proble.It never starts at the selected records and adds up several other random selection. *I started this machine one night after a freeze,the selections wouldn't make,then,after a few minutes,I could make a selection,but the above problem started. I have the manuel,but no troubleshooter tips for this issue. Any help is appreciated Usually a bad ground, quite often on the little cable with the RCA plug. * If you don't know what an RCA plug looks like, do a google images search. *I forget if it only goes to the pulse amp or if it goes in and out of a jack on the way. I got into the machine today and found the whole selector unit loose.I guess after 50+ years and moving, the unit become loose.I adjusted it,checked the play.It seemed to be off 1 digit on a selection,so I moved it a little the other direction and it plays fine. I also cleaned the rca connection since it could have been an issue. Thanks for replys.I appreciate them. Tim |
Thread Tools | |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Thread Starter | Forum | Replies | Last Post |
Tech Tip: Seeburg KD-200 Tormat/Selector issues.... | John Robertson | Juke Boxes | 0 | April 5th 08 05:48 PM |
Wanted: Seeburg G Keyboard Selector Assy | william hill | Juke Boxes | 0 | March 19th 06 06:32 PM |
Tech: Seeburg 222 Tormat Selector tube ? | Barry Schiffer | Juke Boxes | 3 | September 12th 04 10:09 PM |
Seeburg 100B selector problem | Terry Legere & Linda Allen | Juke Boxes | 3 | April 1st 04 01:36 AM |
Seeburg 100 selector question / Advice | Bernie | Juke Boxes | 1 | January 6th 04 01:57 AM |